Subcode: LRFD
Type of connection: Bolted splice connection
Unit system:ย Metric
Designed acc. to:ย AISCย 360-16
Investigated: High-strength bolts in slip-critical connection
Plate material:ย A709, Gr. 50
Bolts: 5/8'' A325
Geometry

Applied load
Bolted splice slip-critical connection is loaded by tension for the slip resistance to be utilized at 100ย %.
Procedure
Concentrically loaded splice bolted connection is designed so that the slip resistance of high strength bolts (AISCย 360-16 โ J3.8) is exhausted first.
Manual calculation
Bolt strength

The design slip strength of the connection is 9ย โย 58.1 = 522.9ย kN.
Strength of plates in tension
Check in IDEAย StatiCa Connection




The bolts are, beside the shear force, loaded also by the tensile force due to the deformation of plates. This decreases the slip resistance of bolts according to AISCย 360-16 โ J3.9. The resistance of connection in IDEAย StatiCa Connection is 497ย kN.
Comparison