Slab
According to EN 1992-1-1, art. 5.3.1(4) a slab is a member, for which the minimum panel dimension is not less than 5 times the overall slab thickness. The slab is loaded only by bending moments and shear forces perpendicular to the centroidal plane of the slab. Detailing provisions check is performed according to EN 1992-1-1, art. 9.3.
Shell as a slab – Shell-slab
The geometry is defined similarly to the slab geometry definition. Unlike the slab, the shell-slab can be loaded by bending and membrane actions. Detailing provisions are checked according to rules for slab (EN 1992-1-1, art. 9.3).
Wall
According to EN 1992-1-1, art. 5.3.1(7) a wall is a member, for which the following principles are not fulfilled:
- the section depth does not exceed 4 times its width
- the height is at least 3 times the section depth
The wall is loaded only by membrane action and detailing provisions are checked according to EN 1992-1-1, art. 9.6.
Shell as wall – Shell-wall
The geometry is defined similarly to the wall geometry definition. Unlike the wall, the shell-wall can be loaded by bending and membrane actions. Detailing provisions are checked according to detailing provisions for wall (EN 1992-1-1, art. 9.6).
Deep beam