Code-check of concrete block according to Hong Kong Code

Cet article est aussi disponible en :
The average stress on a base plate area in contact with concrete is checked against the concrete bearing resistance.

Concrete in bearing

Concrete in bearing is checked according to CoP – SUoS – Cl. 9.4.1 as:

\[ \sigma \le w \]

where:

  • \(\sigma\) – average compressive stress at effective area \(A_{eff}\) which is the intersection of two areas:
    • \(A_{CM}\) – effective area determined according to Cl. 9.4.1 for pure compression
    • \(A_{FEM}\) – area under the base plate in contact with concrete determined by FEA
  • \(w = 0.6 f_{cu}\) – concrete compressive resistance against concentrated load 
  • \(f_{cu}\) – concrete minimum characteristic compressive strength

Effective area \(A_{CM}\) is the area of steel member including stiffeners welded to the base plate increased by overlap \(c\):

\[ c = t_p \sqrt{\frac{p_{yp}}{3w}} \]

where:

  • \(t_p\) – base plate thickness
  • \(p_{yp}\) – design yield strength of the base plate

The pressure under the compression zone is considered as uniform.

Transfer of shear

The shear action at the base plate is assumed to be transferred from the column to the concrete foundation by:

  1. Friction between base plate and concrete/grout
  2. Shear lug
  3. Anchor bolts

Anchors

The tensile forces in anchors include prying forces and are determined by finite element analysis.

Anchors are not checked in the software.

Articles associés

Code-check of bolts and preloaded bolts according to Hong Kong Code

Detailing of bolts and welds according to Hong Kong Code

Ancrage générale

Heavy anchoring design